Added a check to verify the FTDI chip ID before opening the T-Balancer port.
This commit is contained in:
+8
-1
@@ -339,7 +339,7 @@ namespace OpenHardwareMonitor.GUI {
|
||||
y += pair.Value.Count * sensorLineHeight;
|
||||
}
|
||||
y += bottomMargin;
|
||||
y = Math.Max(y, topBorder + bottomBorder + 10);
|
||||
y = Math.Max(y, topBorder + hardwareLineHeight + bottomBorder);
|
||||
this.Size = new Size(width, y);
|
||||
}
|
||||
|
||||
@@ -399,6 +399,13 @@ namespace OpenHardwareMonitor.GUI {
|
||||
|
||||
int x;
|
||||
int y = topMargin;
|
||||
|
||||
if (sensors.Count == 0) {
|
||||
x = leftBorder + 1;
|
||||
g.DrawString("Add a sensor ...", smallFont, Brushes.White,
|
||||
new Rectangle(x, y - 1, w - rightBorder - x, 0));
|
||||
}
|
||||
|
||||
foreach (KeyValuePair<IHardware, IList<ISensor>> pair in sensors) {
|
||||
if (hardwareNames.Value) {
|
||||
if (y > topMargin)
|
||||
|
||||
@@ -41,11 +41,11 @@ using System.Runtime.InteropServices;
|
||||
namespace OpenHardwareMonitor.Hardware.TBalancer {
|
||||
|
||||
internal enum FT_DEVICE : uint {
|
||||
FT_DEVICE_BM,
|
||||
FT_DEVICE_AM,
|
||||
FT_DEVICE_232BM,
|
||||
FT_DEVICE_232AM,
|
||||
FT_DEVICE_100AX,
|
||||
FT_DEVICE_UNKNOWN,
|
||||
FT_DEVICE_2232,
|
||||
FT_DEVICE_2232C,
|
||||
FT_DEVICE_232R,
|
||||
FT_DEVICE_2232H,
|
||||
FT_DEVICE_4232H
|
||||
|
||||
@@ -63,7 +63,15 @@ namespace OpenHardwareMonitor.Hardware.TBalancer {
|
||||
for (int i = 0; i < numDevices; i++) {
|
||||
report.Append("Device Index: ");
|
||||
report.AppendLine(i.ToString(CultureInfo.InvariantCulture));
|
||||
|
||||
report.Append("Device Type: ");
|
||||
report.AppendLine(info[i].Type.ToString());
|
||||
|
||||
// the T-Balancer always uses an FT232BM
|
||||
if (info[i].Type != FT_DEVICE.FT_DEVICE_232BM) {
|
||||
report.AppendLine("Status: Wrong device type");
|
||||
continue;
|
||||
}
|
||||
|
||||
FT_HANDLE handle;
|
||||
FT_STATUS status;
|
||||
status = FTD2XX.FT_Open(i, out handle);
|
||||
|
||||
Reference in New Issue
Block a user