* Bugfix: Fan and Temp data missing #780 * Apply review change request (remove extra comments)
This commit is contained in:
@@ -33,6 +33,7 @@ internal class IT87XX : ISuperIO
|
||||
private readonly byte _version;
|
||||
private readonly float _voltageGain;
|
||||
private IGigabyteController _gigabyteController;
|
||||
private readonly bool _requiresBankSelect; // Fix #780 Set to true for those chips that need a SelectBank(0) to fix dodgy temps and fan speeds
|
||||
|
||||
private bool SupportsMultipleBanks => _bankCount > 1;
|
||||
|
||||
@@ -44,6 +45,7 @@ internal class IT87XX : ISuperIO
|
||||
_dataReg = (ushort)(address + DATA_REGISTER_OFFSET);
|
||||
_gpioAddress = gpioAddress;
|
||||
_gigabyteController = gigabyteController;
|
||||
_requiresBankSelect = false;
|
||||
|
||||
Chip = chip;
|
||||
|
||||
@@ -161,6 +163,7 @@ internal class IT87XX : ISuperIO
|
||||
Temperatures = new float?[6];
|
||||
Fans = new float?[3];
|
||||
Controls = new float?[3];
|
||||
_requiresBankSelect = true;
|
||||
break;
|
||||
|
||||
case Chip.IT8792E:
|
||||
@@ -323,6 +326,9 @@ internal class IT87XX : ISuperIO
|
||||
if (!Mutexes.WaitIsaBus(100))
|
||||
return r.ToString();
|
||||
|
||||
if (_requiresBankSelect)
|
||||
SelectBank(0);
|
||||
|
||||
// dump memory of all banks if supported by chip
|
||||
for (byte b = 0; b < _bankCount; b++)
|
||||
{
|
||||
@@ -401,6 +407,10 @@ internal class IT87XX : ISuperIO
|
||||
if (!Mutexes.WaitIsaBus(10))
|
||||
return;
|
||||
|
||||
// Is this needed on every update? Yes, until a way to detect resume from sleep/hibernation is added, as that invalidates the bank select.
|
||||
if (_requiresBankSelect)
|
||||
SelectBank(0);
|
||||
|
||||
for (int i = 0; i < Voltages.Length; i++)
|
||||
{
|
||||
float value = _voltageGain * ReadByte((byte)(VOLTAGE_BASE_REG + i), out bool valid);
|
||||
|
||||
Reference in New Issue