X570 null exception and pdb in release (#2300)
* X570_MS7C35 nullref Fix nullref * No debug symbols/pdb in release * Update LibreHardwareMonitorLib.csproj
This commit is contained in:
@@ -6099,22 +6099,21 @@ internal sealed class SuperIOHardware : Hardware
|
||||
{
|
||||
if (_motherboard.Model == Model.X570_MS7C35) // Add Temp Value for CPU MOS TEMPERATURE & PCH TEMPERATURE
|
||||
{
|
||||
float voltage;
|
||||
float? voltage = null;
|
||||
|
||||
if (sensor.Index == 24)
|
||||
{
|
||||
voltage = (float)_readVoltage(6);
|
||||
voltage = _readVoltage(6);
|
||||
}
|
||||
else if (sensor.Index == 25)
|
||||
{
|
||||
voltage = (float)_readVoltage(11);
|
||||
}
|
||||
else
|
||||
{
|
||||
voltage = 0;
|
||||
voltage = _readVoltage(11);
|
||||
}
|
||||
|
||||
double R = (10000.0 * voltage / (2.048 - 1.0)); //Convert voltage measured to resistance value
|
||||
if (!voltage.HasValue || voltage.Value <= 0)
|
||||
continue;
|
||||
|
||||
double R = (10000.0 * voltage.Value / (2.048 - 1.0)); //Convert voltage measured to resistance value
|
||||
double T = ((298.15 * 3435.0) / ((298.15 * Math.Log(R / 10000.0)) + 3435.0)); // Use R value in steinhart and hart equation, calculate temperature value in kelvin
|
||||
float Tc = (float)(T - 273.15); // Converting kelvin to celsius
|
||||
|
||||
|
||||
Reference in New Issue