Fix some code analysis issues (#841)
This commit is contained in:
@@ -32,7 +32,7 @@ namespace LibreHardwareMonitor.Hardware.Controller.AquaComputer
|
||||
//Reading output report instead of feature report, as the measurements are in the output report
|
||||
_stream.Read(_rawData);
|
||||
|
||||
Name = $"D5Next";
|
||||
Name = "D5Next";
|
||||
FirmwareVersion = Convert.ToUInt16(_rawData[14] | (_rawData[13] << 8));
|
||||
_temperatures[0] = new Sensor("Water Temperature", 0, SensorType.Temperature, this, Array.Empty<ParameterDescription>(), settings);
|
||||
ActivateSensor(_temperatures[0]);
|
||||
@@ -60,7 +60,7 @@ namespace LibreHardwareMonitor.Hardware.Controller.AquaComputer
|
||||
//Reading output report instead of feature report, as the measurements are in the output report
|
||||
_stream.Read(_rawData);
|
||||
_temperatures[0].Value = (_rawData[88] | (_rawData[87] << 8)) / 100f; //Water Temp
|
||||
_rpmSensors[0].Value = (_rawData[117] | (_rawData[116] << 8)); //Pump RPM
|
||||
_rpmSensors[0].Value = _rawData[117] | (_rawData[116] << 8); //Pump RPM
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -10,6 +10,9 @@ namespace LibreHardwareMonitor.Hardware.Controller.AquaComputer
|
||||
{
|
||||
internal sealed class MPS : Hardware
|
||||
{
|
||||
public const int ExternalTemperature = 43;
|
||||
public const int InternalWaterTemperature = 45;
|
||||
public const int PumpFlow = 35;
|
||||
private const byte MPS_REPORT_ID = 0x2;
|
||||
|
||||
private readonly Sensor _pumpFlow;
|
||||
@@ -79,9 +82,9 @@ namespace LibreHardwareMonitor.Hardware.Controller.AquaComputer
|
||||
if (_rawData[0] != MPS_REPORT_ID)
|
||||
return;
|
||||
|
||||
_pumpFlow.Value = BitConverter.ToUInt16(_rawData, MPSDataIndexes.PumpFlow) / 10f;
|
||||
_pumpFlow.Value = BitConverter.ToUInt16(_rawData, PumpFlow) / 10f;
|
||||
|
||||
_externalTemperature = BitConverter.ToUInt16(_rawData, MPSDataIndexes.ExternalTemperature);
|
||||
_externalTemperature = BitConverter.ToUInt16(_rawData, ExternalTemperature);
|
||||
//sensor reading returns Int16.MaxValue (32767), when not connected
|
||||
if (_externalTemperature != short.MaxValue)
|
||||
{
|
||||
@@ -92,19 +95,12 @@ namespace LibreHardwareMonitor.Hardware.Controller.AquaComputer
|
||||
_temperatures[0].Value = null;
|
||||
}
|
||||
|
||||
_temperatures[1].Value = BitConverter.ToUInt16(_rawData, MPSDataIndexes.InternalWaterTemperature) / 100f;
|
||||
_temperatures[1].Value = BitConverter.ToUInt16(_rawData, InternalWaterTemperature) / 100f;
|
||||
}
|
||||
|
||||
private ushort ExtractFirmwareVersion()
|
||||
{
|
||||
return BitConverter.ToUInt16(_rawData, 3);
|
||||
}
|
||||
|
||||
private sealed class MPSDataIndexes
|
||||
{
|
||||
public const int ExternalTemperature = 43;
|
||||
public const int InternalWaterTemperature = 45;
|
||||
public const int PumpFlow = 35;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -25,7 +25,7 @@ namespace LibreHardwareMonitor.Hardware.Controller.AquaComputer
|
||||
//Reading output report instead of feature report, as the measurements are in the output report
|
||||
_stream.Read(_rawData);
|
||||
|
||||
Name = $"OCTO";
|
||||
Name = "OCTO";
|
||||
FirmwareVersion = GetConvertedValue(OctoDataIndexes.FIRMWARE_VERSION).GetValueOrDefault(0);
|
||||
|
||||
// Initialize the 4 temperature sensors
|
||||
|
||||
Reference in New Issue